Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
Healthcare (Basel) ; 12(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38727488

RESUMO

Lower back pain, a common issue among pregnant women, often complicates daily activities like standing up from a chair. Therefore, research into the standing motion of pregnant women is important, and many research studies have already been conducted. However, many of these studies were conducted in highly controlled environments, overlooking everyday scenarios such as using a desk for support when standing up, and their effects have not been adequately tested. To address this gap, we measured multimodal signals for a sit-to-stand (STS) movement with hand assistance and verified the changes using a t-test. To avoid imposing strain on pregnant women, we used 10 non-diseased young adults who wore jackets designed to simulate pregnancy conditions, thus allowing for more comprehensive and rigorous experimentation. We attached surface electromyography (sEMG) sensors to the erector spinae muscles of participants and measured changes in muscle activity, skeletal positioning, and center of pressure both before and after wearing a Maternity-Simulation Jacket. Our analysis showed that the jacket successfully mimicked key aspects of the movement patterns typical in pregnant women. These results highlight the possibility of developing practical strategies that more accurately mirror the real-life scenarios met by pregnant women, enriching the current research on their STS movement.

2.
PLoS One ; 19(5): e0302308, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38709812

RESUMO

Rheumatoid arthritis causes joint inflammation due to immune abnormalities, resulting in joint pain and swelling. In recent years, there have been considerable advancements in the treatment of this disease. However, only approximately 60% of patients achieve remission. Patients with multifactorial diseases shift between states from day to day. Patients may remain in a good or poor state with few or no transitions, or they may switch between states frequently. The visualization of time-dependent state transitions, based on the evaluation axis of stable/unstable states, may provide useful information for achieving rheumatoid arthritis treatment goals. Energy landscape analysis can be used to quantitatively determine the stability/instability of each state in terms of energy. Time-series clustering is another method used to classify transitions into different groups to identify potential patterns within a time-series dataset. The objective of this study was to utilize energy landscape analysis and time-series clustering to evaluate multidimensional time-series data in terms of multistability. We profiled each patient's state transitions during treatment using energy landscape analysis and time-series clustering. Energy landscape analysis divided state transitions into two patterns: "good stability leading to remission" and "poor stability leading to treatment dead-end." The number of patients whose disease status improved increased markedly until approximately 6 months after treatment initiation and then plateaued after 1 year. Time-series clustering grouped patients into three clusters: "toward good stability," "toward poor stability," and "unstable." Patients in the "unstable" cluster are considered to have clinical courses that are difficult to predict; therefore, these patients should be treated with more care. Early disease detection and treatment initiation are important. The evaluation of state multistability enables us to understand a patient's current state in the context of overall state transitions related to rheumatoid arthritis drug treatment and to predict future state transitions.


Assuntos
Antirreumáticos , Artrite Reumatoide , Artrite Reumatoide/tratamento farmacológico , Humanos , Análise por Conglomerados , Antirreumáticos/uso terapêutico , Feminino , Pessoa de Meia-Idade , Masculino , Estudos de Coortes , Idoso , Adulto , Fatores de Tempo
3.
Exp Cell Res ; 439(1): 114057, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38679315

RESUMO

Certain oncogenes, including mutant RAS and BRAF, induce a type of senescence known as oncogene-induced senescence (OIS) in normal cells in a cell-type-specific manner. OIS serves as a barrier to transformation by activated oncogenes. Our previous studies showed that mutant KRASV12 did not efficiently induce OIS in an hTERT/Cdk4-immortalized normal human bronchial epithelial cell line (HBEC3), but it did enhance both anchorage-dependent and anchorage-independent growth. In this study, we investigated whether mutant BRAF, a well-known inducer of OIS, could trigger OIS in HBEC3 cells. We also assessed the impact of mutant BRAF on the growth of HBEC3 cells, as no previous studies have examined this using a normal bronchial epithelial cell line model. We established an HBEC3 cell line, designated as HBEC3-BIN, that expresses mutant BRAFV600E in a doxycycline-regulated manner. Unlike our previous finding that KRASV12 upregulated both pERK and pAKT, mutant BRAFV600E upregulated pERK but not pAKT in HBEC3-BIN cells. Similar to KRASV12, BRAFV600E did not efficiently induce OIS. Interestingly, while BRAFV600E inhibited colony formation in anchorage-dependent conditions, it dramatically enhanced colony formation in anchorage-independent conditions in HBEC3-BIN. In HBEC3 cells without BRAFV600E or KRASV12 expression, p21 was only detected in the cytoplasm, and its localization was not altered by the expression of BRAFV600E or KRASV12. Next-generation sequencing analysis revealed an enrichment of gene sets known to be involved in carcinogenesis, including IL3/JAK/STAT3, IL2, STAT5, and the EMT pathway. Our results indicate that, unlike KRASV12, which promoted both, BRAFV600E enhances anchorage-independent growth but inhibits anchorage-dependent growth of HBEC3. This contrast may result from differences in activation signaling in the downstream pathways. Furthermore, HBEC3 cells appear to be inherently resistant to OIS, which may be partly due to the fact that p21 remains localized in the cytoplasm upon expression of BRAFV600E or KRASV12.

4.
Cureus ; 16(3): e56400, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633943

RESUMO

We report the rare case of an 80-year-old man with hepatocellular carcinoma that ruptured in the gallbladder, causing a cystic artery pseudoaneurysm and hemobilia. Emergency transarterial embolization (TAE) successfully controlled the bleeding without causing ischemic cholecystitis. Cone-beam computed tomography angiography was useful in identifying the bleeding branch of the selectively embolized cystic artery. Although the patient had poor liver function (Child-Pugh class C) before TAE, it remarkably improved after embolization due to the resolution of coagulopathy and obstructive jaundice caused by hemobilia. TAE was considered useful for this rare clinical condition.

5.
Acta Med Okayama ; 78(2): 135-142, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38688831

RESUMO

This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.


Assuntos
Meios de Contraste , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Meios de Contraste/química , Tomografia Computadorizada por Raios X/métodos , Iodo , Humanos
6.
Curr Oncol Rep ; 26(5): 573-582, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38625653

RESUMO

PURPOSE OF REVIEW: To review the current status of kidney tumor ablation in patients with substantial kidney impairment. RECENT FINDINGS: Few reports of kidney tumor ablation in such patients have recently been published. The reported prevalence of patients with stage 4 or 5 chronic kidney disease (CKD) among patients undergoing ablation is 2.0%-10%. In patients with stage 4 or 5 CKD, local tumor control rates were 88%-100%. The effect of ablation on CKD stage is unclear, and the observed deteriorations in kidney function are consistent with both the effect of cryoablation and the natural course of advanced CKD. According to guidelines, active surveillance may be selected. The goals of treatment are complete tumor removal and maintenance of kidney function, both of which can be met by ablation. Given the limited treatment options, ablation may play a pivotal role in the management of patients with advanced CKD.


Assuntos
Neoplasias Renais , Insuficiência Renal Crônica , Humanos , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Neoplasias Renais/complicações , Insuficiência Renal Crônica/complicações , Criocirurgia , Técnicas de Ablação/métodos
7.
Jpn J Radiol ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551772

RESUMO

The advent of Deep Learning (DL) has significantly propelled the field of diagnostic radiology forward by enhancing image analysis and interpretation. The introduction of the Transformer architecture, followed by the development of Large Language Models (LLMs), has further revolutionized this domain. LLMs now possess the potential to automate and refine the radiology workflow, extending from report generation to assistance in diagnostics and patient care. The integration of multimodal technology with LLMs could potentially leapfrog these applications to unprecedented levels.However, LLMs come with unresolved challenges such as information hallucinations and biases, which can affect clinical reliability. Despite these issues, the legislative and guideline frameworks have yet to catch up with technological advancements. Radiologists must acquire a thorough understanding of these technologies to leverage LLMs' potential to the fullest while maintaining medical safety and ethics. This review aims to aid in that endeavor.

8.
Jpn J Radiol ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38388790

RESUMO

PURPOSE: To retrospectively evaluate the depiction rate of feeding arteries in biopsy-proven clear cell renal cell carcinoma (CCRCC) on four-dimensional computed tomography angiography (4D-CTA) images. MATERIALS AND METHODS: This study included 22 patients with 22 CCRCC and 30 feeding arteries treated with transcatheter renal artery embolization. The depiction rate of the feeding arteries on preprocedural 4D-CTA was evaluated. Images were acquired by 320-row multi-detector computed tomography (CT) 15‒36 s after starting to inject a contrast agent (600 mg/kg iodine) intravenously into patients at 2.1 s intervals (11 phases). Two board-certified radiologists retrospectively assessed the feeder depiction rate in all 11 phases with reference to the procedural images as the gold standard. Discrepancies were resolved by consultation with a third radiologist. RESULTS: Among the feeders, 11 (36.7%) were segmental or lobar, and 19 (63.3%) were interlobar or arcuate arteries. The feeder depiction rate was the highest (25 [83.3%] of 30) in the 5th phase (delay, 23.4 s) where the gap in contrast enhancement between the renal artery and cortex was the largest. This was followed by the 6th (23 [76.7%] of 30), 4th (22 [73.3%] of 30]), and 7th (21 [70.0%] of 30) phases. The overall rate of depicting feeding arteries in the 11 phases of 4D-CTA was 28 (93.3%) of 30. CONCLUSIONS: The depiction rate of CCRCC feeding arteries including lobar or smaller artery branches by 4D-CTA was favorable. The feeding arteries were optimally visualized during the phase with the largest contrast gap between the renal artery and cortex.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38206125

RESUMO

We report a case of postoperative pseudoaneurysm, successfully treated with selective arterial embolization, using a steerable microcatheter and triaxial system via retrograde approach. A pseudoaneurysm was detected in the dorsal pancreatic artery, a severely narrow and steeply inverted branch of the superior mesenteric artery, making microcatheter insertion via the antegrade approach challenging. However, a steerable microcatheter was advanced beyond the orifice and the tip was reversed, changing the route to retrograde allowing for easy insertion of the microguidewire. Subsequently, a small microcatheter was advanced beyond the pseudoaneurysm into the dorsal pancreatic artery, and arterial embolization was successfully completed without complications.

10.
Int J Clin Oncol ; 29(2): 81-88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37115426

RESUMO

Interventional oncology offers minimally invasive treatments for malignant tumors for curative and palliative purposes based on the percutaneous insertion of needles or catheters into the target location under image guidance. Robotic systems have been gaining increasing attention as tools that provide potential advantages for image-guided interventions. Among the robotic systems developed for intervention, those relevant to the oncology field are mainly those for guiding or driving the needles in non-vascular interventional procedures such as biopsy and tumor ablation. Needle-guiding robots support planning the needle path and align the needle robotically according to the planned trajectory, which is combined with subsequent manual needle insertion by the physician through the needle guide. Needle-driving robots can advance the needle robotically after determining its orientation. Although a wide variety of robotic systems have been developed, only a limited number of these systems have reached the clinical phase or commercialization thus far. The results of previous studies suggest that such interventional robots have the potential to increase the accuracy of needle placement, facilitate out-of-plane needle insertion, decrease the learning curve, and reduce radiation exposure. On the other hand, increased complexity and costs may be a concern when using robotic systems compared with conventional manual procedures. Further data should be collected to comprehensively assess the value of robotic systems in interventional oncology.


Assuntos
Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Agulhas , Biópsia
11.
Jpn J Radiol ; 42(3): 319-325, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37833443

RESUMO

PURPOSE: This single-center, single-arm, prospective, open-label study was conducted to evaluate the optimal number of cores (single or multiple) in renal tumor biopsy. MATERIALS AND METHODS: Forty-four biopsies of 44 tumors (mean diameter, 2.7 ± 1.0 cm; range, 1.6-5.0 cm) were included. Biopsy was performed under ultrasound or computed tomography fluoroscopy guidance using an 18-gauge cutting needle and the co-axial method. Two or more specimens were obtained, which were divided into first and subsequent specimens. "First specimen" and "all specimens" were histologically evaluated (i.e., appropriateness of specimen, histological diagnosis, subtype, and Fuhrman grade of renal cell carcinoma [RCC]) blindly and independently by two board-certified pathologists. RESULTS: Multiple specimens were successfully and safely obtained in all the biopsies. All tumors were histologically diagnosed; 40 malignancies included 39 RCCs and 1 solitary fibrous tumor, and 4 benign lesions included 2 angiomyolipomas, 1 oncocytoma, and 1 capillary hemangioma. In all RCCs, the subtype could be determined (32 clear cell RCCs, 4 chromophobe RCCs, and 3 papillary RCCs), and the Furman grade was determined in 38 RCCs. When only the first specimen was evaluated, 22.7% of the specimens were inappropriate for diagnosis, and 34 (77.3%) were histologically diagnosed. The diagnostic yield was significantly lower than that of all specimens (P = 0.0044). Univariate analysis revealed that smaller lesions were a significant predictor of diagnostic failure (P = 0.020). CONCLUSION: Biopsy with multiple cores significantly improved diagnostic yield. Thus, operators should obtain multiple cores during renal tumor biopsy.


Assuntos
Adenoma Oxífilo , Carcinoma de Células Renais , Neoplasias Renais , Humanos , Adenoma Oxífilo/patologia , Biópsia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X , Estudos Prospectivos
12.
Jpn J Radiol ; 42(1): 3-15, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37540463

RESUMO

In this review, we address the issue of fairness in the clinical integration of artificial intelligence (AI) in the medical field. As the clinical adoption of deep learning algorithms, a subfield of AI, progresses, concerns have arisen regarding the impact of AI biases and discrimination on patient health. This review aims to provide a comprehensive overview of concerns associated with AI fairness; discuss strategies to mitigate AI biases; and emphasize the need for cooperation among physicians, AI researchers, AI developers, policymakers, and patients to ensure equitable AI integration. First, we define and introduce the concept of fairness in AI applications in healthcare and radiology, emphasizing the benefits and challenges of incorporating AI into clinical practice. Next, we delve into concerns regarding fairness in healthcare, addressing the various causes of biases in AI and potential concerns such as misdiagnosis, unequal access to treatment, and ethical considerations. We then outline strategies for addressing fairness, such as the importance of diverse and representative data and algorithm audits. Additionally, we discuss ethical and legal considerations such as data privacy, responsibility, accountability, transparency, and explainability in AI. Finally, we present the Fairness of Artificial Intelligence Recommendations in healthcare (FAIR) statement to offer best practices. Through these efforts, we aim to provide a foundation for discussing the responsible and equitable implementation and deployment of AI in healthcare.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Algoritmos , Radiologistas , Atenção à Saúde
13.
Jpn J Radiol ; 42(2): 158-164, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37633874

RESUMO

Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.


Assuntos
Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Intensificação de Imagem Radiográfica/métodos , Fótons , Ossículos da Orelha/diagnóstico por imagem
14.
Cardiovasc Intervent Radiol ; 47(1): 132-138, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38010507

RESUMO

PURPOSE: To evaluate the detection rate of feeding arteries in renal cell carcinoma with automated feeder-detection software and determine the optimal imaging phase for accurate feeder detection with transarterial time-resolved computed tomography angiography. MATERIALS AND METHODS: The performance of automated feeder-detection software was retrospectively evaluated using transarterial renal time-resolved computed tomography angiography images of 15 renal cell carcinomas (mean size, 22.1 mm); the images were obtained via the renal artery using a hybrid angio-CT system with 320-row computed tomography, across nine phases with 0.5-s intervals over a contrast delay time of 1.0-5.0 s. Automated feeder-detection software was applied to each phase in all tumors (135 image series in total). The feeder-detection rate (i.e., sensitivity) in each phase was evaluated, and the number of false feeders demonstrated by the software was counted for each tumor. RESULTS: A total of 22 feeders were identified. The feeder-detection rate was the highest (95.5% [21/22]) at delay times of 1.5 s and 2.0 s and lower in later phases. At delay times of 1.0 s and 1.5 s, the software demonstrated no or only a few (≤ 3) false feeders in 93.3% (14/15) of the tumors. In later phases, however, many (≥ 4) false feeders were observed in > 50% of tumors. CONCLUSION: The automated feeder-detection software showed a favorable feeder-detection rate and may be useful in transarterial embolization for renal cell carcinoma. The optimal delay time to avoid the demonstration of false feeders and achieve a high detection accuracy was 1.5 s. LEVEL OF EVIDENCE IV: Case Series.


Assuntos
Carcinoma Hepatocelular , Carcinoma de Células Renais , Quimioembolização Terapêutica , Neoplasias Renais , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Angiografia por Tomografia Computadorizada , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada por Raios X , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/terapia , Software
15.
Jpn J Radiol ; 42(4): 398-405, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37991654

RESUMO

PURPOSE: To retrospectively assess the time course of complications after image-guided small renal mass biopsy using initial follow-up imaging. MATERIALS AND METHODS: A total of 190 masses (mean, 2.1 ± 0.70 cm; range, 0.6-3.8 cm) were assessed using initial computed tomography (43 non-enhanced and 141 enhanced) or magnetic resonance imaging (five non-enhanced and one enhanced) after biopsy. Initial follow-up imaging was classified into two groups (i.e., with or without hematoma) and various factors were compared. RESULTS: The masses were histologically diagnosed in all patients except one. Post-procedural complications included 129 Grade I hematomas, 1 Grade I hemothorax, 9 Grade II hematomas, and 1 Grade IIIa pneumothorax. Residual 28 Grade I and 6 Grade II hematomas and 8 new complications (6 small hematomas, 1 pseudoaneurysm, and 1 arteriovenous fistula) were observed on the initial follow-up imaging obtained at a median of 21 days (3-90 days) after the biopsy. On the initial follow-up imaging, the groups with and without hematoma differed significantly in the following factors: age (P = 0.04), size (P = 0.02), guided images (P < 0.01), hematoma at the end of the procedure (P < 0.01), and days after biopsy (P < 0.01). Although three masses exhibited > 25% shrinkage, no significant change was observed in mass diameter on initial follow-up imaging (mean, 2.1 ± 0.71 cm; P = 0.90). CONCLUSION: Initial follow-up imaging after a biopsy revealed improvements in most of the complications, a few new complications, and an unchanged mass diameter.


Assuntos
Neoplasias Renais , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Estudos Retrospectivos , Seguimentos , Biópsia/efeitos adversos , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Biópsia Guiada por Imagem/efeitos adversos
16.
J Radiat Res ; 65(1): 1-9, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-37996085

RESUMO

This review provides an overview of the application of artificial intelligence (AI) in radiation therapy (RT) from a radiation oncologist's perspective. Over the years, advances in diagnostic imaging have significantly improved the efficiency and effectiveness of radiotherapy. The introduction of AI has further optimized the segmentation of tumors and organs at risk, thereby saving considerable time for radiation oncologists. AI has also been utilized in treatment planning and optimization, reducing the planning time from several days to minutes or even seconds. Knowledge-based treatment planning and deep learning techniques have been employed to produce treatment plans comparable to those generated by humans. Additionally, AI has potential applications in quality control and assurance of treatment plans, optimization of image-guided RT and monitoring of mobile tumors during treatment. Prognostic evaluation and prediction using AI have been increasingly explored, with radiomics being a prominent area of research. The future of AI in radiation oncology offers the potential to establish treatment standardization by minimizing inter-observer differences in segmentation and improving dose adequacy evaluation. RT standardization through AI may have global implications, providing world-standard treatment even in resource-limited settings. However, there are challenges in accumulating big data, including patient background information and correlating treatment plans with disease outcomes. Although challenges remain, ongoing research and the integration of AI technology hold promise for further advancements in radiation oncology.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Radioterapia Guiada por Imagem , Humanos , Inteligência Artificial , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias/radioterapia , Radioterapia (Especialidade)/métodos
17.
Aging Cell ; 23(2): e14043, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38111237

RESUMO

Inflammatory cytokines released by synovium after trauma disturb the gene regulatory network and have been implicated in the pathophysiology of osteoarthritis. A mechanistic understanding of how aging perturbs this process can help identify novel interventions. Here, we introduced network paradigms to simulate cytokine-mediated pathological communication between the synovium and cartilage. Cartilage-specific network analysis of injured young and aged murine knees revealed aberrant matrix remodeling as a transcriptomic response unique to aged knees displaying accelerated cartilage degradation. Next, network-based cytokine inference with pharmacological manipulation uncovered IL6 family member, Oncostatin M (OSM), as a driver of the aberrant matrix remodeling. By implementing a phenotypic drug discovery approach, we identified that the activation of OSM recapitulated an "inflammatory" phenotype of knee osteoarthritis and highlighted high-value targets for drug development and repurposing. These findings offer translational opportunities targeting the inflammation-driven osteoarthritis phenotype.


Assuntos
Osteoartrite do Joelho , Camundongos , Animais , Oncostatina M/genética , Oncostatina M/metabolismo , Inflamação , Fenótipo
18.
J Physiol ; 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38099335

RESUMO

Accumulated fat in skeletal muscle (i.e. myosteatosis), common in sedentary older individuals, compromises skeletal muscle health and function. A mechanistic understanding of how physical activity levels dictate fat accumulation represents a critical step towards establishment of therapies that promote healthy ageing. Using a network medicine paradigm that characterized the transcriptomic response of aged muscle to exercise versus immobilization protocols, this study explored the shared molecular cascade that regulates the fate of fibro-adipogenic progenitors (FAPs), the cell population primarily responsible for fat accumulation. Specifically, gene set enrichment analyses with network propagation revealed Pgc-1α as a functional hub of a large gene regulatory network underlying the regulation of FAPs by physical activity in aged muscle, but not in young counterparts. Integrated in silico and in situ approaches to induce Pgc-1α overexpression in aged muscle promoted mitochondrial fatty acid oxidation and inhibited FAP adipogenesis. These findings suggest that the Pgc-1α-mitochondrial fatty acid oxidation axis is a shared mechanism by which physical activity regulates age-related myosteatosis. The network medicine paradigm introduced provides mechanistic insight into exercise adaptation in elderly skeletal muscle and offers translational opportunities to advance exercise prescription for older populations. KEY POINTS: Fat accumulation is a quintessential feature of aged skeletal muscle. While increasing physical activity levels has been proposed as an effective strategy to reduce the fat in skeletal muscle (i.e. myosteatosis), the molecular cascade underlying these benefits has been poorly defined. This study implemented a series of network medicine approaches and uncovered Pgc-1α as a mechanistic driver of the regulation of fibro-adipogenic progenitors (FAPs) by physical activity. Integrated in silico and in situ approaches to induce Pgc-1α overexpression promoted mitochondrial fatty acid oxidation and inhibited FAP adipogenesis. Together, the findings of the current study suggest a novel hypothesis that physical activity reduces myosteatosis via upregulation of Pgc-1α-mediated mitochondrial fatty acid oxidation and subsequent inhibition of FAP adipogenesis.

19.
Acta Med Okayama ; 77(6): 665-669, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38145942

RESUMO

We report the case details of a 65-year-old Japanese man with an omental abscess that was discovered 43 days after he underwent a laparoscopic proximal gastrectomy for gastric cancer. His chief complaint was mild abdominal pain that had persisted for several days. The abscess was diagnosed as a rare postoperative complication. We hesitated to perform a reoperation given the invasiveness of general anesthesia and surgery, plus the possibility of postoperative adhesions and because the patient's general condition was stable and he had only mild abdominal pain. Percutaneous drainage using a 10.2-F catheter was performed with the patient under conscious sedation and computed tomography-fluoroscopy guidance, with no complications. After the procedure, the size of the abscess cavity was remarkably reduced, and 23 days later the catheter was withdrawn.


Assuntos
Abscesso , Laparoscopia , Masculino , Humanos , Idoso , Abscesso/etiologia , Drenagem/efeitos adversos , Drenagem/métodos , Gastrectomia/efeitos adversos , Dor Abdominal/complicações , Laparoscopia/efeitos adversos , Laparoscopia/métodos
20.
Korean J Radiol ; 24(10): 952-959, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37793668

RESUMO

Large language models (LLMs) such as ChatGPT have garnered considerable interest for their potential to aid non-native English-speaking researchers. These models can function as personal, round-the-clock English tutors, akin to how Prometheus in Greek mythology bestowed fire upon humans for their advancement. LLMs can be particularly helpful for non-native researchers in writing the Introduction and Discussion sections of manuscripts, where they often encounter challenges. However, using LLMs to generate text for research manuscripts entails concerns such as hallucination, plagiarism, and privacy issues; to mitigate these risks, authors should verify the accuracy of generated content, employ text similarity detectors, and avoid inputting sensitive information into their prompts. Consequently, it may be more prudent to utilize LLMs for editing and refining text rather than generating large portions of text. Journal policies concerning the use of LLMs vary, but transparency in disclosing artificial intelligence tool usage is emphasized. This paper aims to summarize how LLMs can lower the barrier to academic writing in English, enabling researchers to concentrate on domain-specific research, provided they are used responsibly and cautiously.


Assuntos
Inteligência Artificial , Redação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA